QSHC

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

Quality and Safety in Health Care 2007;16:279-284; doi:10.1136/qshc.2006.019497
Copyright © 2007 by the BMJ Publishing Group Ltd.

This Article
Free to AccessThis article has been Unlocked
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Franklin, B. D.
Right arrow Articles by Barber, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Franklin, B. D.
Right arrow Articles by Barber, N.

ERROR MANAGEMENT

The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study

Bryony Dean Franklin1, Kara O’Grady1, Parastou Donyai2, Ann Jacklin1, Nick Barber3

1 Centre for Medicines Safety and Service Quality, Pharmacy Department, Hammersmith Hospitals NHS Trust, The School of Pharmacy, University of London, London, UK
2 Department of Pharmacy, Kingston University, Surrey, UK
3 Department of Practice and Policy, The School of Pharmacy, University of London, London, UK

Correspondence to:
Professor B D Franklin
Department of Pharmacy, Hammersmith Hospital, Du Cane Road, London,W12 0HS, UK; bdean{at}hhnt.nhs.uk
ABSTRACT
Objectives: To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time.

Design, setting and participants: Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward.

Intervention: Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system.

Main outcome measures: Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks.

Results: Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; {chi}2 test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; {chi}2 test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p<0.001; {chi}2 test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; {chi}2 test).

Conclusions: A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.


Abbreviations: EMAR, electronic medication administration record; IV, intravenous; MAE, medication administration error; OE, opportunities for error




This article has been cited by other articles:


Home page
Qual Saf Health CareHome page
N. Barber, T. Cornford, and E. Klecun
Qualitative evaluation of an electronic prescribing and administration system
Qual. Saf. Health Care, August 1, 2007; 16(4): 271 - 278.
[Abstract] [Full Text] [PDF]