QSHC

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Husch, M
Right arrow Articles by Noskin, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Husch, M
Right arrow Articles by Noskin, G
Topic Collections
Right arrowRelated Article
Qual Saf Health Care 2005;14:80-86
© 2005 BMJ Publishing Group Ltd.


ORIGINAL ARTICLE

Insights from the sharp end of intravenous medication errors: implications for infusion pump technology

M Husch, C Sullivan, D Rooney, C Barnard, M Fotis, J Clarke, G Noskin

Northwestern Memorial Hospital, Feinberg School of Medicine, Northwestern University, Chicago, USA

Correspondence to:
M Husch
Research Pharmacist Coordinator, Patient Safety Team, Northwestern Memorial Hospital, 676 North St Claire, Chicago, IL 60611, USA; mhusch{at}nmh.org Background: Intravenous (IV) medication errors are a common type of error identified in hospitals and can lead to considerable harm. Over the past 20 years there have been several hundred FDA reported incidents involving IV pumps, many of which have led to patient deaths.

Objective: To determine the actual types, frequency, and severity of medication errors associated with IV pumps. To evaluate the likelihood that smart pump technology without an interface to other systems could have prevented errors.

Methods: Using a point prevalence approach, investigators prospectively compared the medication, dose, and infusion rate on the IV pump with the prescribed medication, doses, and rate in the medical record. Preventability with smart pump technology was retrospectively determined based on a rigorous definition of currently available technology.

Results: A total of 426 medications were observed infusing through an IV pump. Of these, 285 (66.9%) had one or more errors associated with their administration. There were 389 documented errors overall; 37 were "rate deviation" errors and three of these were judged to be due to a programming mistake. Most of the documented events would not have caused patient harm (NCC MERP category C). Only one error would have been prevented by smart pump technology without additional interface and software capabilities.

Conclusion: Medication errors associated with IV pumps occur frequently, have the potential to cause harm, and are epidemiologically diverse. Smart pumps are a necessary component of a comprehensive safe medication system. However, currently available smart pumps will fail to generate meaningful improvements in patient safety until they can be interfaced with other systems such as the electronic medical record, computerized prescriber order entry, bar coded medication administration systems, and pharmacy information systems. Future research should focus on the effectiveness of new technology in preventing latent and active errors, and on new types of error that any technology can introduce.


Abbreviations: BCMA, bar coded medication administration; CPOE, computerized prescriber order entry; EMR, electronic medical record; PIS, pharmacy information system

Keywords: intravenous administration; intravenous pump; medication error; smart pump


Related Article

Quality Lines
Qual. Saf. Health Care 2005 14: 73. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
NeoReviewsHome page
F. H. Morriss Jr
Adverse Medical Events in the NICU: Epidemiology and Prevention
NeoReviews, January 1, 2008; 9(1): e8 - e23.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
C. S. Hankin, J. Schein, J. A. Clark, and S. Panchal
Adverse events involving intravenous patient-controlled analgesia
Am. J. Health Syst. Pharm., July 15, 2007; 64(14): 1492 - 1499.
[Abstract] [Full Text] [PDF]


Home page
Qual Saf Health CareHome page
M K Szekendi, C Sullivan, A Bobb, J Feinglass, D Rooney, C Barnard, and G A Noskin
Active surveillance using electronic triggers to detect adverse events in hospitalized patients.
Qual. Saf. Health Care, June 1, 2006; 15(3): 184 - 190.
[Abstract] [Full Text] [PDF]


Home page
Qual Saf Health CareHome page
K Taxis
Who is responsible for the safety of infusion devices? It's high time for action!
Qual. Saf. Health Care, April 1, 2005; 14(2): 76 - 76.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2005 by the BMJ Publishing Group Ltd.