QSHC

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Apkon, M
Right arrow Articles by Vitale, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Apkon, M
Right arrow Articles by Vitale, R
Topic Collections
Right arrowRelevant Article
Qual Saf Health Care 2004;13:265-271
© 2004 BMJ Publishing Group Ltd & Institute for Healthcare Improvement


ORIGINAL ARTICLE

Design of a safer approach to intravenous drug infusions: failure mode effects analysis

M Apkon1, J Leonard2, L Probst2, L DeLizio1, R Vitale2

1 Yale University School of Medicine, New Haven, CT, USA
2 Yale-New Haven Hospital, New Haven, CT, USA

Correspondence to:
Associate Professor M Apkon
Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06520-8064, USA; michael.apkon{at}yale.edu Objectives: A set of standard processes was developed for delivering continuous drug infusions in order to improve (1) patient safety; (2) efficiency in staff workflow; (3) hemodynamic stability during infusion changes, and (4) efficient use of resources. Failure modes effects analysis (FMEA) was used to examine the impact of process changes on the reliability of delivering drug infusions.

Setting: An 11 bed multidisciplinary pediatric ICU in the children’s hospital of an academic medical center staffed by board certified pediatric intensivists. The hospital uses computerized physician order entry for all medication orders.

Methods: A multidisciplinary team characterized key elements of the drug infusion process. The process was enhanced to increase overall reliability and the original and revised processes were compared using FMEA. Resource consumption was estimated by reviewing purchasing and pharmacy records for the calendar year after full implementation of the revised process. Staff satisfaction was evaluated using an anonymous questionnaire administered to staff nurses in the ICU and pediatric residents who had rotated through the ICU.

Results: The original process was characterized by six elements: selecting the drug; selecting a dose; selecting an infusion rate; calculating and ordering the infusion; preparing the infusion; programming the infusion pump and delivering the infusion. The following practice changes were introduced: standardizing formulations for all infusions; developing database driven calculators; extending infusion hang times from 24 to 72 hours; changing from bedside preparation by nurses to pharmacy prepared or premanufactured solutions. FMEA showed that the last three elements of the original process had high risk priority numbers (RPNs) of >225 whereas the revised process had no elements with RPNs >100. The combined effect of prolonging infusion hang times, preparation in the pharmacy, and purchasing premanufactured solutions resulted in 1500 fewer infusions prepared by nurses per year. Nursing staff expressed a significant preference and pediatric residents unanimously expressed a strong preference for the revised process.

Conclusions: Standardization of infusion delivery reduced the frequency for completing the most unreliable elements of the process and reduced the riskiness of the individual elements. Both contribute to a safer system.


Abbreviations: CPOE, computerized physician order entry; FMEA, failure mode effects analysis; ICU, intensive care unit

Keywords: patient safety; medication errors; drug infusions; computerized decision support; paediatric intensive care


Relevant Article

FMEA and RCA: the mantras; of modern risk management
J W Senders
Qual. Saf. Health Care 2004 13: 249-250. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
PediatricsHome page
Council on Clinical Information Technology
Pediatric Aspects of Inpatient Health Information Technology Systems
Pediatrics, December 1, 2008; 122(6): e1287 - e1296.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
K. Nemec, H. Kopelent-Frank, and R. Greif
Standardization of infusion solutions to reduce the risk of incompatibility
Am. J. Health Syst. Pharm., September 1, 2008; 65(17): 1648 - 1654.
[Abstract] [Full Text] [PDF]


Home page
J Antimicrob ChemotherHome page
M. Gilchrist, B. D. Franklin, and J. P. Patel
An outpatient parenteral antibiotic therapy (OPAT) map to identify risks associated with an OPAT service
J. Antimicrob. Chemother., July 1, 2008; 62(1): 177 - 183.
[Abstract] [Full Text] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
R. Sorokin and J. E. Gottlieb
Enhancing Patient Safety During Feeding-Tube Insertion: A Review of More Than 2000 Insertions
JPEN J Parenter Enteral Nutr, September 1, 2006; 30(5): 440 - 445.
[Abstract] [Full Text] [PDF]


Home page
Am J Health Syst PharmHome page
T. B. Wetterneck, K. A. Skibinski, T. L. Roberts, S. M. Kleppin, M. E. Schroeder, M. Enloe, S. S. Rough, A. S. Hundt, and P. Carayon
Using failure mode and effects analysis to plan implementation of smart i.v. pump technology.
Am. J. Health Syst. Pharm., August 15, 2006; 63(16): 1528 - 1538.
[Abstract] [Full Text] [PDF]


Home page
Qual Saf Health CareHome page
C M van Tilburg, I P Leistikow, C M A Rademaker, M B Bierings, and A T H van Dijk
Health care failure mode and effect analysis: a useful proactive risk analysis in a pediatric oncology ward
Qual. Saf. Health Care, February 1, 2006; 15(1): 58 - 63.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
G. Y. Larsen, H. B. Parker, J. Cash, M. O'Connell, and M. C. Grant
Standard Drug Concentrations and Smart-Pump Technology Reduce Continuous-Medication-Infusion Errors in Pediatric Patients
Pediatrics, July 1, 2005; 116(1): e21 - e25.
[Abstract] [Full Text] [PDF]


Home page
Qual Saf Health CareHome page
J W Senders
FMEA and RCA: the mantras; of modern risk management
Qual. Saf. Health Care, August 1, 2004; 13(4): 249 - 250.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2004 by the BMJ Publishing Group Ltd.