QSHC

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cooper, J. B
Right arrow Articles by McPeek, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cooper, J. B
Right arrow Articles by McPeek, B.
Qual Saf Health Care 2002;11:277-282
© 2002 Quality and Safety in Health Care


CLASSIC PAPER

Preventable anesthesia mishaps: a study of human factors*

Jeffrey B Cooper, Ronald S Newbower, Charlene D Long, Bucknam McPeek1

1 Laboratories of the Bioengineering Unit, Department of Anaesthesia, Harvard Medical School at the Massachusetts General Hospital, Boston, Massachusetts 02114, USA


ABSTRACT
A modified critical-incident analysis technique was used in a retrospective examination of the characteristics of human error and equipment failure in anesthetic practice. The objective was to uncover patterns of frequently occurring incidents that are in need of careful prospective investigation. Forty seven interviews were conducted with staff and resident anesthesiologists at one urban teaching institution, and descriptions of 359 preventable incidents were obtained. Twenty three categories of details from these descriptions were subjected to computer-aided analysis for trends and patterns. Most of the preventable incidents involved human error (82%), with breathing-circuit disconnections, inadvertent changes in gas flow, and drug syringe errors being frequent problems. Overt equipment failures constituted only 14% of the total number of preventable incidents, but equipment design was indictable in many categories of human error, as were inadequate experience and insufficient familiarity with equipment or with the specific surgical procedure. Other factors frequently associated with incidents were inadequate communication among personnel, haste or lack of precaution, and distraction. Results from multi-hospital studies based on the methodology developed could be used for more objective determination of priorities and planning of specific investments for decreasing the risk associated with anesthesia.


Keywords: anaesthesia; safety; accidents; equipment failure




This article has been cited by other articles:


Home page
Br J AnaesthHome page
D. Phipps, G. H. Meakin, P. C. W. Beatty, C. Nsoedo, and D. Parker
Human factors in anaesthetic practice: insights from a task analysis
Br. J. Anaesth., March 1, 2008; 100(3): 333 - 343.
[Abstract] [Full Text] [PDF]


Home page
ASH Education BookHome page
W. H. Dzik
Technology for Enhanced Transfusion Safety
Hematology, January 1, 2005; 2005(1): 476 - 482.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
W. Lederer and A. Benzer
Programming errors from patient-controlled analgesia
Can J Anesth, October 1, 2003; 50(8): 854 - 855.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2002 by the BMJ Publishing Group Ltd.